Photo of Prof Ahmed Elsheikh

Prof Ahmed Elsheikh PhD, CEng, MICE

Professor of Biomaterial Mechanics Civil Engineering and Industrial Design

    Publications

    2018

    Biomechanical behaviour - Anisotropy of eye cornea through experimental strip tests (Conference Paper)

    Arsalan Khan, M., Elsheikh, A., & Ahmad Khan, I. (2018). Biomechanical behaviour – Anisotropy of eye cornea through experimental strip tests. In IOP Conference Series: Materials Science and Engineering Vol. 310 (pp. 012075). doi:10.1088/1757-899X/310/1/012075

    DOI: 10.1088/1757-899X/310/1/012075

    Changes in Corneal Biomechanical Properties With Different Corneal Cross-linking Irradiances (Journal article)

    Bao, F., Zheng, Y., Liu, C., Zheng, X., Zhao, Y., Wang, Y., . . . Elsheikh, A. (2018). Changes in Corneal Biomechanical Properties With Different Corneal Cross-linking Irradiances. JOURNAL OF REFRACTIVE SURGERY, 34(1), 51-+. doi:10.3928/1081597X-20171025-01

    DOI: 10.3928/1081597X-20171025-01

    Clinical evaluation of a new correction Check for updatem algorithm for dynamic Scheimpflug analyzer tonometry before and after laser in situ keratomileusis and small-incision lenticule extraction (Journal article)

    Chen, K. -J., Joda, A., Vinciguerra, R., Eliasy, A., Sefat, S. M. M., Kook, D., . . . Elsheikh, A. (2018). Clinical evaluation of a new correction Check for updatem algorithm for dynamic Scheimpflug analyzer tonometry before and after laser in situ keratomileusis and small-incision lenticule extraction. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 44(5), 581-588. doi:10.1016/j.jcrs.2018.01.023

    DOI: 10.1016/j.jcrs.2018.01.023

    Development and clinical verification of numerical simulation for laser in situ keratomileusis (Journal article)

    Bao, F., Wang, J., Cao, S., Liao, N., Shu, B., Zhao, Y., . . . Elsheikh, A. (2018). Development and clinical verification of numerical simulation for laser in situ keratomileusis. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 83, 126-134. doi:10.1016/j.jmbbm.2018.04.016

    DOI: 10.1016/j.jmbbm.2018.04.016

    Ex-vivo experimental validation of biomechanically-corrected intraocular pressure measurements on human eyes using the CorVis ST. (Journal article)

    Eliasy, A., Chen, K. -J., Vinciguerra, R., Maklad, O., Vinciguerra, P., Ambrósio, R., . . . Elsheikh, A. (2018). Ex-vivo experimental validation of biomechanically-corrected intraocular pressure measurements on human eyes using the CorVis ST.. Experimental eye research, 175, 98-102. doi:10.1016/j.exer.2018.06.013

    DOI: 10.1016/j.exer.2018.06.013

    Intelligent Planning for Laser Refractive Surgeries (Conference Paper)

    Wang, W., Yue, Y., Elsheikh, A., & Bao, F. (2018). Intelligent Planning for Laser Refractive Surgeries. In Journal of Physics: Conference Series Vol. 976 (pp. 012009). doi:10.1088/1742-6596/976/1/012009

    DOI: 10.1088/1742-6596/976/1/012009

    MURINE CRUCIATE LIGAMENT PATHOLOGY DURING OSTEOARTHRITIS DEVELOPMENT (Conference Paper)

    Ramos, L., Bou-Gharios, G., Pitsillides, A., Elsheikh, A., Comerford, E., & Poulet, B. (2018). MURINE CRUCIATE LIGAMENT PATHOLOGY DURING OSTEOARTHRITIS DEVELOPMENT. In OSTEOARTHRITIS AND CARTILAGE Vol. 26 (pp. S400-S401). Retrieved from http://gateway.webofknowledge.com/

    Non-Orthogonal Corneal Astigmatism among Normal and Keratoconic Brazilian and Chinese populations (Journal article)

    Abass, A., Clamp, J., Bao, F., Jr, A. R., & Elsheikh, A. (2018). Non-Orthogonal Corneal Astigmatism among Normal and Keratoconic Brazilian and Chinese populations. CURRENT EYE RESEARCH, 43(6), 717-724. doi:10.1080/02713683.2018.1433858

    DOI: 10.1080/02713683.2018.1433858

    Numerical study of the effect of head and eye movement on progression of retinal detachment (Journal article)

    Vroon, J., de Jong, J. H., Aboulatta, A., Eliasy, A., van der Helm, F. C. T., van Meurs, J. C., . . . Elsheikh, A. (2018). Numerical study of the effect of head and eye movement on progression of retinal detachment. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 17(4), 975-983. doi:10.1007/s10237-018-1006-y

    DOI: 10.1007/s10237-018-1006-y

    Positions of Ocular Geometrical and Visual Axes in Brazilian, Chinese and Italian Populations. (Journal article)

    Abass, A., Vinciguerra, R., Lopes, B. T., Bao, F., Vinciguerra, P., Ambrósio, R., & Elsheikh, A. (2018). Positions of Ocular Geometrical and Visual Axes in Brazilian, Chinese and Italian Populations.. Current eye research, 1-11. doi:10.1080/02713683.2018.1500609

    DOI: 10.1080/02713683.2018.1500609

    Should the Corvis Biomechanical Index (CBI) Include Corneal Thickness Parameters? (Journal article)

    Vinciguerra, R., Jr, A. R., Roberts, C. J., Elsheikh, A., Lopes, B., & Vinciguerra, P. (2018). Should the Corvis Biomechanical Index (CBI) Include Corneal Thickness Parameters?. JOURNAL OF REFRACTIVE SURGERY, 34(3). Retrieved from http://gateway.webofknowledge.com/

    The Relationship Between Mechanical Properties, Ultrastructural Changes, and Intrafibrillar Bond Formation in Corneal UVA/Riboflavin Cross-linking Treatment for Keratoconus (Journal article)

    Chang, S. -H., Mohammadvali, A., Chen, K. -J., Ji, Y. -R., Young, T. -H., Wang, T. -J., . . . Elsheikh, A. (2018). The Relationship Between Mechanical Properties, Ultrastructural Changes, and Intrafibrillar Bond Formation in Corneal UVA/Riboflavin Cross-linking Treatment for Keratoconus. JOURNAL OF REFRACTIVE SURGERY, 34(4), 264-+. doi:10.3928/1081597X-20180220-01

    DOI: 10.3928/1081597X-20180220-01

    2017

    A Novel Peptide Hydrogel for an Antimicrobial Bandage Contact Lens (Thesis / Dissertation)

    Gallagher, A. (2017, October 17). A Novel Peptide Hydrogel for an Antimicrobial Bandage Contact Lens.

    A viscoelastic anisotropic hyperelastic constitutive model of the human cornea (Journal article)

    Whitford, C., Movchan, N. V., Studer, H., & Elsheikh, A. (2018). A viscoelastic anisotropic hyperelastic constitutive model of the human cornea. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 17(1), 19-29. doi:10.1007/s10237-017-0942-2

    DOI: 10.1007/s10237-017-0942-2

    Application of particle swarm optimization in inverse finite element modeling to determine the cornea 's mechanical behavior (Journal article)

    Magalhaes, R., Elsheikh, A., Buchler, P., Whitford, C., & Wang, J. (2017). Application of particle swarm optimization in inverse finite element modeling to determine the cornea 's mechanical behavior. ACTA SCIENTIARUM-TECHNOLOGY, 39(3), 325-331. doi:10.4025/actascitechnol.v39i3.29884

    DOI: 10.4025/actascitechnol.v39i3.29884

    Changes in biomechanically corrected intraocular pressure and dynamic corneal response parameters before and after transepithelial photorefractive keratectomy and femtosecond laser-assisted laser in situ keratomileusis (Journal article)

    Lee, H., Roberts, C. J., Kim, T. -I., Jr, A. R., Elsheikh, A., & Kang, D. S. Y. (2017). Changes in biomechanically corrected intraocular pressure and dynamic corneal response parameters before and after transepithelial photorefractive keratectomy and femtosecond laser-assisted laser in situ keratomileusis. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 43(12), 1495-1503. doi:10.1016/j.jcrs.2017.08.019

    DOI: 10.1016/j.jcrs.2017.08.019

    Corneal Biomechanics in Ectatic Diseases: Refractive Surgery Implications. (Journal article)

    Ambrósio, R., Correia, F. F., Lopes, B., Salomão, M. Q., Luz, A., Dawson, D. G., . . . Roberts, C. J. (2017). Corneal Biomechanics in Ectatic Diseases: Refractive Surgery Implications.. The open ophthalmology journal, 11, 176-193. doi:10.2174/1874364101711010176

    DOI: 10.2174/1874364101711010176

    Effect of accelerated corneal crosslinking combined with transepithelial photorefractive keratectomy on dynamic corneal response parameters and biomechanically corrected intraocular pressure measured with a dynamic Scheimpflug analyzer in healthy myopic patients (Journal article)

    Lee, H., Roberts, C. J., Jr, A. R., Elsheikh, A., Kang, D. S. Y., & Kim, T. -I. (2017). Effect of accelerated corneal crosslinking combined with transepithelial photorefractive keratectomy on dynamic corneal response parameters and biomechanically corrected intraocular pressure measured with a dynamic Scheimpflug analyzer in healthy myopic patients. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 43(7), 937-945. doi:10.1016/j.jcrs.2017.04.036

    DOI: 10.1016/j.jcrs.2017.04.036

    Effects of diabetes mellitus on biomechanical properties of the rabbit cornea (Journal article)

    Bao, F., Deng, M., Zheng, X., Li, L., Zhao, Y., Cao, S., . . . Elsheikh, A. (2017). Effects of diabetes mellitus on biomechanical properties of the rabbit cornea. EXPERIMENTAL EYE RESEARCH, 161, 82-88. doi:10.1016/j.exer.2017.05.015

    DOI: 10.1016/j.exer.2017.05.015

    Evaluating the repeatability of corneal elevation through calculating the misalignment between Successive topography measurements during the follow up of LASIK (Journal article)

    Zheng, X., Yang, W., Huang, L., Wang, J., Cao, S., Geraghty, B., . . . Elsheikh, A. (2017). Evaluating the repeatability of corneal elevation through calculating the misalignment between Successive topography measurements during the follow up of LASIK. SCIENTIFIC REPORTS, 7. doi:10.1038/s41598-017-03223-9

    DOI: 10.1038/s41598-017-03223-9

    Integration of Scheimpflug-Based Corneal Tomography and Biomechanical Assessments for Enhancing Ectasia Detection (Journal article)

    Jr, A. R., Lopes, B. T., Faria-Correia, F., Salomao, M. Q., Buhren, J., Roberts, C. J., . . . Vinciguerra, P. (2017). Integration of Scheimpflug-Based Corneal Tomography and Biomechanical Assessments for Enhancing Ectasia Detection. JOURNAL OF REFRACTIVE SURGERY, 33(7), 434-+. doi:10.3928/1081597X-20170426-02

    DOI: 10.3928/1081597X-20170426-02

    Introduction of Two Novel Stiffness Parameters and Interpretation of Air Puff-Induced Biomechanical Deformation Parameters With a Dynamic Scheimpflug Analyzer (Journal article)

    Roberts, C. J., Mahmoud, A. M., Bons, J. P., Hossain, A., Elsheikh, A., Vinciguerra, R., . . . Jr, A. R. (2017). Introduction of Two Novel Stiffness Parameters and Interpretation of Air Puff-Induced Biomechanical Deformation Parameters With a Dynamic Scheimpflug Analyzer. JOURNAL OF REFRACTIVE SURGERY, 33(4), 266-+. doi:10.3928/1081597X-20161221-03

    DOI: 10.3928/1081597X-20161221-03

    Repeatability and Reproducibility of Intraocular Pressure and Dynamic Corneal Response Parameters Assessed by the Corvis ST (Journal article)

    Lopes, B. T., Roberts, C. J., Elsheikh, A., Vinciguerra, R., Vinciguerra, P., Reisdorf, S., . . . Jr, A. R. (2017). Repeatability and Reproducibility of Intraocular Pressure and Dynamic Corneal Response Parameters Assessed by the Corvis ST. JOURNAL OF OPHTHALMOLOGY. doi:10.1155/2017/8515742

    DOI: 10.1155/2017/8515742

    Repeatability of corneal elevation maps in keratoconus patients using the tomography matching method (Journal article)

    Zheng, Y., Huang, L., Zhao, Y., Wang, J., Zheng, X., Huang, W., . . . Elsheikh, A. (2017). Repeatability of corneal elevation maps in keratoconus patients using the tomography matching method. SCIENTIFIC REPORTS, 7. doi:10.1038/s41598-017-17658-7

    DOI: 10.1038/s41598-017-17658-7

    The hierarchical response of human corneal collagen to load (Journal article)

    Bell, J. S., Hayes, S., Whitford, C., Sanchez-Weatherby, J., Shebanova, O., Vergari, C., . . . Meek, K. M. (2018). The hierarchical response of human corneal collagen to load. ACTA BIOMATERIALIA, 65, 216-225. doi:10.1016/j.actbio.2017.11.015

    DOI: 10.1016/j.actbio.2017.11.015

    VISCOELASTIC BEHAVIOUR OF THE CANINE CRANIAL CRUCIATE LIGAMENT COMPLEX (Thesis / Dissertation)

    Hama Rashid, R. A. (2017). VISCOELASTIC BEHAVIOUR OF THE CANINE CRANIAL CRUCIATE LIGAMENT COMPLEX. (The University of Liverpool).

    2016

    A New Stiffness Parameter in Air Puff Induced Corneal Deformation Analysis (Conference Paper)

    Roberts, C. J., Mahmoud, A. M., Bons, J., Hossain, A., Elsheikh, A., Vinciguerra, R., . . . Ambrosio, R. (2016). A New Stiffness Parameter in Air Puff Induced Corneal Deformation Analysis. In INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE Vol. 57. Retrieved from http://gateway.webofknowledge.com/

    Changes in posterior scleral collagen microstructure in canine eyes with an ADAMTS10 mutation (Journal article)

    Boote, C., Palko, J. R., Sorensen, T., Mohammadvali, A., Elsheikh, A., Komaromy, A. M., . . . Liu, J. (2016). Changes in posterior scleral collagen microstructure in canine eyes with an ADAMTS10 mutation. MOLECULAR VISION, 22, 503-517. Retrieved from http://gateway.webofknowledge.com/

    Clinical Evaluation of Methods to Correct Intraocular Pressure Measurements by the Goldmann Applanation Tonometer, Ocular Response Analyzer, and Corvis ST Tonometer for the Effects of Corneal Stiffness Parameters (Journal article)

    Bao, F., Huang, Z., Huang, J., Wang, J., Deng, M., Li, L., . . . Elsheikh, A. (2016). Clinical Evaluation of Methods to Correct Intraocular Pressure Measurements by the Goldmann Applanation Tonometer, Ocular Response Analyzer, and Corvis ST Tonometer for the Effects of Corneal Stiffness Parameters. JOURNAL OF GLAUCOMA, 25(6), 510-519. doi:10.1097/IJG.0000000000000359

    DOI: 10.1097/IJG.0000000000000359

    Consideration of corneal biomechanics in the diagnosis and management of keratoconus: is it important? (Journal article)

    Bao, F., Geraghty, B., Wang, Q., & Elsheikh, A. (2016). Consideration of corneal biomechanics in the diagnosis and management of keratoconus: is it important?. Eye and vision (London, England), 3, 18. doi:10.1186/s40662-016-0048-4

    DOI: 10.1186/s40662-016-0048-4

    Detection of Keratoconus With a New Biomechanical Index (Journal article)

    Vinciguerra, R., Jr, A. R., Elsheikh, A., Roberts, C. J., Lopes, B., Morenghi, E., . . . Vinciguerra, P. (2016). Detection of Keratoconus With a New Biomechanical Index. JOURNAL OF REFRACTIVE SURGERY, 32(12), 803-+. doi:10.3928/1081597X-20160629-01

    DOI: 10.3928/1081597X-20160629-01

    Development and validation of a correction equation for Corvis tonometry. (Journal article)

    Joda, A. A., Shervin, M. M. S., Kook, D., & Elsheikh, A. (2016). Development and validation of a correction equation for Corvis tonometry.. Computer methods in biomechanics and biomedical engineering, 19(9), 943-953. doi:10.1080/10255842.2015.1077515

    DOI: 10.1080/10255842.2015.1077515

    Ectasia Detection by the Assessment of Corneal Biomechanics (Journal article)

    Jr, A. R., Lopes, B., Faria-Correia, F., Vinciguerra, R., Vinciguerra, P., Elsheikh, A., & Roberts, C. J. (2016). Ectasia Detection by the Assessment of Corneal Biomechanics. CORNEA, 35(7), e18-e20. doi:10.1097/ICO.0000000000000875

    DOI: 10.1097/ICO.0000000000000875

    Ex vivo testing of intact eye globes under inflation conditions to determine regional variation of mechanical stiffness. (Journal article)

    Whitford, C., Joda, A., Jones, S., Bao, F., Rama, P., & Elsheikh, A. (2016). Ex vivo testing of intact eye globes under inflation conditions to determine regional variation of mechanical stiffness.. Eye and vision (London, England), 3, 21. doi:10.1186/s40662-016-0052-8

    DOI: 10.1186/s40662-016-0052-8

    Influence of Pachymetry and Intraocular Pressure on Dynamic Corneal Response Parameters in Healthy Patients (Journal article)

    Vinciguerra, R., Elsheikh, A., Roberts, C. J., Jr, A. R., Kang, D. S. Y., Lopes, B. T., . . . Vinciguerra, P. (2016). Influence of Pachymetry and Intraocular Pressure on Dynamic Corneal Response Parameters in Healthy Patients. JOURNAL OF REFRACTIVE SURGERY, 32(8), 550-561. doi:10.3928/1081597X-20160524-01

    DOI: 10.3928/1081597X-20160524-01

    Numerical simulation of corneal refractive surgery based on improved reconstruction of corneal surface (Thesis / Dissertation)

    Wang, J. (2016, April 7). Numerical simulation of corneal refractive surgery based on improved reconstruction of corneal surface.

    Reconstruction of 3D surface maps from anterior segment optical coherence tomography images using graph theory and genetic algorithms (Journal article)

    Williams, D., Zheng, Y., Davey, P. G., Bao, F., Shen, M., & Elsheikh, A. (2016). Reconstruction of 3D surface maps from anterior segment optical coherence tomography images using graph theory and genetic algorithms. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 25, 91-98. doi:10.1016/j.bspc.2015.11.004

    DOI: 10.1016/j.bspc.2015.11.004

    Role of corneal biomechanics in the diagnosis and management of keratoconus (Chapter)

    Bao., Geraghty., Wang, Q. M., & Elsheikh, A. (2016). Role of corneal biomechanics in the diagnosis and management of keratoconus. In J. L. Alió (Ed.), Keratoconus Recent Advances in Diagnosis and Treatment. Springer.

    2015

    Analysis of corneal biomechanics using ultra high-speed Scheimpflug imaging to distinguish normal from keratoconic patients (Conference Paper)

    Vinciguerra, R., Ambrosio, R., Elsheikh, A., Lopes, B., Morenghi, E., Donati, S., . . . Vinciguerra, P. (2015). Analysis of corneal biomechanics using ultra high-speed Scheimpflug imaging to distinguish normal from keratoconic patients. In INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE Vol. 56. Retrieved from http://gateway.webofknowledge.com/

    Biomechanical model of the human cornea: Considering shear stiffness and regional variation of collagen anisotropy and density (Journal article)

    Whitford, C., Studer, H., Boote, C., Meek, K. M., & Elsheikh, A. (2015). Biomechanical model of the human cornea: Considering shear stiffness and regional variation of collagen anisotropy and density. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 42, 76-87. doi:10.1016/j.jmbbm.2014.11.006

    DOI: 10.1016/j.jmbbm.2014.11.006

    Clinical Evaluation of Correction Algorithm for Corvis ST Tonometry (Conference Paper)

    Elsheikh, A., Joda, A., Vinciguerra, R., Vinciguerra, P., Kook, D., Sefat, S., & Bao, F. (2015). Clinical Evaluation of Correction Algorithm for Corvis ST Tonometry. In INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE Vol. 56. Retrieved from http://gateway.webofknowledge.com/

    Design of peptide gels for bandage contact lenses (Conference Paper)

    Williams, R., Gallagher, A., Elsheikh, A., & Wellings, D. (2015). Design of peptide gels for bandage contact lenses. In INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE Vol. 56. Retrieved from http://gateway.webofknowledge.com/

    Development and validation of a correction equation for Corvis tonometry (Journal article)

    Joda, A. A., Shervin, M. M. S., Kook, D., & Elsheikh, A. (2016). Development and validation of a correction equation for Corvis tonometry. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 19(9), 943-953. doi:10.1080/10255842.2015.1077515

    DOI: 10.1080/10255842.2015.1077515

    Effect of Misalignment between Successive Corneal Videokeratography Maps on the Repeatability of Topography Data (Journal article)

    Bao, F., Wang, J., Huang, J., Yu, Y., Deng, M., Li, L., . . . Elsheikh, A. (2015). Effect of Misalignment between Successive Corneal Videokeratography Maps on the Repeatability of Topography Data. PLOS ONE, 10(11). doi:10.1371/journal.pone.0139541

    DOI: 10.1371/journal.pone.0139541

    Effect of translation and rotation fitting on analysis of corneal topography. (Journal article)

    Deng, M. L., Li, L. N., Huang, L. F., Wang, W., Yu, A. Y., Huang, J. H., . . . Elsheikh, A. (2015). Effect of translation and rotation fitting on analysis of corneal topography.. Journal of medical engineering & technology, 39(6), 309-315. doi:10.3109/03091902.2015.1040174

    DOI: 10.3109/03091902.2015.1040174

    Evaluation of the relationship of corneal biomechanical metrics with physical intraocular pressure and central corneal thickness in ex vivo rabbit eye globes (Journal article)

    Bao, F., Deng, M., Wang, Q., Huang, J., Yang, J., Whitford, C., . . . Elsheikh, A. (2015). Evaluation of the relationship of corneal biomechanical metrics with physical intraocular pressure and central corneal thickness in ex vivo rabbit eye globes. EXPERIMENTAL EYE RESEARCH, 137, 11-17. doi:10.1016/j.exer.2015.05.018

    DOI: 10.1016/j.exer.2015.05.018

    Fast segmentation of anterior segment optical coherence tomography images using graph cut. (Journal article)

    Williams, D., Zheng, Y., Bao, F., & Elsheikh, A. (2015). Fast segmentation of anterior segment optical coherence tomography images using graph cut.. Eye and Vision, 2, 1. doi:10.1186/s40662-015-0011-9

    DOI: 10.1186/s40662-015-0011-9

    In vivo study of corneal responses to increased intraocular pressure loading. (Journal article)

    Elsheikh, A., McMonnies, C. W., Whitford, C., & Boneham, G. C. (2015). In vivo study of corneal responses to increased intraocular pressure loading.. Eye and Vision, 2, 20. doi:10.1186/s40662-015-0029-z

    DOI: 10.1186/s40662-015-0029-z

    Individual-specific microstructural characterisation of human ocular tunics for whole eye numerical modelling (Conference Paper)

    Spang, M., Sorensen, T., Whitford, C., Elsheikh, A., & Boote, C. (2015). Individual-specific microstructural characterisation of human ocular tunics for whole eye numerical modelling. In INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE Vol. 56. Retrieved from http://gateway.webofknowledge.com/

    Reliability of the Effect of Artificial Anterior Chamber Pressure and Corneal Drying on Corneal Graft Thickness (Journal article)

    Romano, V., Steger, B., Chen, J. Y., Hassaan, S., Batterbury, M., Willoughby, C. E., . . . Kaye, S. B. (2015). Reliability of the Effect of Artificial Anterior Chamber Pressure and Corneal Drying on Corneal Graft Thickness. CORNEA, 34(8), 866-869. doi:10.1097/ICO.0000000000000451

    DOI: 10.1097/ICO.0000000000000451

    The effect of anterior chamber pressure and corneal drying on corneal thickness in preparation for descemet stripping endothelial keratoplasty (DSAEK) (Conference Paper)

    Steger, B., Romano, V., Hassaan, S., Batterbury, M., Ahmad, S., Willoughby, C. E., . . . Kaye, S. B. (2015). The effect of anterior chamber pressure and corneal drying on corneal thickness in preparation for descemet stripping endothelial keratoplasty (DSAEK). In INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE Vol. 56. Retrieved from http://gateway.webofknowledge.com/

    2014

    Age-Related Variation in the Biomechanical and Structural Properties of the Corneo-Scleral Tunic (Chapter)

    Geraghty, B., Whitford, C., Boote, C., Akhtar, R., & Elsheikh, A. (2014). Age-Related Variation in the Biomechanical and Structural Properties of the Corneo-Scleral Tunic. In Mechanical Properties of Aging Soft Tissues (pp. 207-235). Springer. doi:10.1007/978-3-319-03970-1_9

    DOI: 10.1007/978-3-319-03970-1_9

    Assessment of the Ocular Response Analyzer as an Instrument for Measurement of Intraocular Pressure and Corneal Biomechanics (Journal article)

    Elsheikh, A., Joda, A., Abass, A., & Garway-Heath, D. (2015). Assessment of the Ocular Response Analyzer as an Instrument for Measurement of Intraocular Pressure and Corneal Biomechanics. CURRENT EYE RESEARCH, 40(11), 1111-1119. doi:10.3109/02713683.2014.978479

    DOI: 10.3109/02713683.2014.978479

    Corneal topography matching by iterative registration (Journal article)

    Wang, J., Elsheikh, A., Davey, P. G., Wang, W., Bao, F., & Mottershead, J. E. (2014). Corneal topography matching by iterative registration. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 228(11), 1154-1167. doi:10.1177/0954411914559080

    DOI: 10.1177/0954411914559080

    Numerical Representation of Collagen Fibril Anisotropic and Density Related Stiffness: The Intact Human Eye Globe (Poster)

    Elsheikh, A., Whitford, C., Hassaan, S., Mohammadvali, A., Magalhaes, R., & Boote, C. (2014). Numerical Representation of Collagen Fibril Anisotropic and Density Related Stiffness: The Intact Human Eye Globe. Poster session presented at the meeting of Unknown Conference. Retrieved from http://gateway.webofknowledge.com/

    THE CONTRIBUTION OF PROTEOGLYCANS TO THE VISCOELASTICITY OF THE CANINE ANTERIOR CRUCIATE LIGAMENT (Conference Paper)

    Comerford, E. J., Geraghty, B., Hamarashid, R., & Elsheikh, A. (2014). THE CONTRIBUTION OF PROTEOGLYCANS TO THE VISCOELASTICITY OF THE CANINE ANTERIOR CRUCIATE LIGAMENT. In OSTEOARTHRITIS AND CARTILAGE Vol. 22 (pp. S313). doi:10.1016/j.joca.2014.02.579

    DOI: 10.1016/j.joca.2014.02.579

    2013

    A 3D segmentation framework for cornea segmentation in anterior segment OCT images using level set technique with shape prior (Conference Paper)

    Williams, D., Zheng, Y., & Elsheikh, A. (2013). A 3D segmentation framework for cornea segmentation in anterior segment OCT images using level set technique with shape prior. In MIUA (pp. 1-8). Birminham: BMVC.

    A wide-angle X-ray fibre diffraction method for quantifying collagen orientation across large tissue areas: application to the human eyeball coat (Journal article)

    Pijanka, J. K., Abass, A., Sorensen, T., Elsheikh, A., & Boote, C. (2013). A wide-angle X-ray fibre diffraction method for quantifying collagen orientation across large tissue areas: application to the human eyeball coat. Journal of Applied Crystallography, 46(5), 1481-1489. doi:10.1107/S0021889813022358

    DOI: 10.1107/S0021889813022358

    Automatic segmentation of anterior segment optical coherence tomography images (Conference Paper)

    Williams, D., Zheng, Y., Bao, F., & Elsheikh, A. (2013). Automatic segmentation of anterior segment optical coherence tomography images. In JOURNAL OF BIOMEDICAL OPTICS Vol. 18. doi:10.1117/1.JBO.18.5.056003

    DOI: 10.1117/1.JBO.18.5.056003

    Automatic segmentation of anterior segment optical coherence tomography images (Journal article)

    Williams, D., Zheng, Y., Bao, F., & Elsheikh, A. (2013). Automatic segmentation of anterior segment optical coherence tomography images. Journal of Biomedical Optics, 18(5), 056003. doi:10.1117/1.JBO.18.5.056003

    DOI: 10.1117/1.JBO.18.5.056003

    Clinical evaluation of multiparameter correction equations for Goldmann applanation tonometry (Journal article)

    Davey, P. G., Elsheikh, A., & Garway-Heath, D. F. (2013). Clinical evaluation of multiparameter correction equations for Goldmann applanation tonometry. Eye, 27(5), 621-629. doi:10.1038/eye.2013.23

    DOI: 10.1038/eye.2013.23

    Correction factors for Goldmann Tonometry (Journal article)

    Elsheikh, A., Gunvant, P., Jones, S. W., Pye, D., & Garway-Heath, D. F. (2013). Correction factors for Goldmann Tonometry. Journal of Glaucoma, 22(2). doi:10.1097/IJG.0b013e3182312010

    DOI: 10.1097/IJG.0b013e3182312010

    Evaluation of the Shape Symmetry of Bilateral Normal Corneas in a Chinese Population (Journal article)

    Bao, F. J., Chen, H., Yu, Y., Yu, J. G., Zhou, S., Wang, J., . . . Elsheikh, A. (2013). Evaluation of the Shape Symmetry of Bilateral Normal Corneas in a Chinese Population. PLOS ONE.

    Influence of glucocorticosteroids on the biomechanical properties of in-vivo rabbit cornea (Journal article)

    Yu, J. -G., Bao, F. -J., Joda, A., Fu, X. -A., Zhou, S., Wang, J., . . . Elsheikh, A. (2014). Influence of glucocorticosteroids on the biomechanical properties of in-vivo rabbit cornea. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 29, 350-359. doi:10.1016/j.jmbbm.2013.08.015

    DOI: 10.1016/j.jmbbm.2013.08.015

    Regional Variation of Biomechanical Properties of Intact Eye Globes (Conference Paper)

    Elsheikh, A., Whitford, C., Joda, A., Abass, A., Bao, F., & Rama, P. (2013). Regional Variation of Biomechanical Properties of Intact Eye Globes. In ARVO 2013 Annual Meeting (pp. 1631). Seattle, Washington: ARVO.

    2012

    Age-related variations in the biomechanical properties of human sclera (Journal article)

    Geraghty, B., Jones, S. W., Rama, P., Akhtar, R., & Elsheikh, A. (2012). Age-related variations in the biomechanical properties of human sclera. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 16, 181-191. doi:10.1016/j.jmbbm.2012.10.011

    DOI: 10.1016/j.jmbbm.2012.10.011

    Assessment of the Ocular Response Analyzer as a tool for measuring intraocular pressure and corneal biomechanical properties (Conference Paper)

    Elsheikh, A., & Garway-Heath, D. F. (2012). Assessment of the Ocular Response Analyzer as a tool for measuring intraocular pressure and corneal biomechanical properties. In 8th European Solid Mechanics Conference. Graz.

    Complete Map of Collagen Fibre Orientation Across the Human Eyeball Coat (Conference Paper)

    Pijanka, J., Abass, A., Sorensen, T., Elsheikh, A., & Boote, C. (2012). Complete Map of Collagen Fibre Orientation Across the Human Eyeball Coat. In CITeR2012 (pp. 72-80). Bristol: CITeR. Retrieved from http://www.citer.wvu.edu/

    Complete Map of Collagen Fibre Orientation Across the Human Eyeball Coat (Conference Paper)

    Pijanka, J., Abass, A., Sorensen, T., Elsheikh, A., & Boote, C. (2012). Complete Map of Collagen Fibre Orientation Across the Human Eyeball Coat. In Meeting of Institute of Tissue Engineering and Repair. Cardiff.

    Corneal Mechanical Stiffness and its Effect on Tonometry (Journal article)

    Elsheikh, A. (2012). Corneal Mechanical Stiffness and its Effect on Tonometry. Journal of Glaucoma, 1. doi:10.1097/IJG.0b013e318252d3af

    DOI: 10.1097/IJG.0b013e318252d3af

    In Vivo Evidence for a Bridging Role of a Collagen V Subtype at the Epidermis–Dermis Interface (Journal article)

    Bonod-Bidaud, C., Roulet, M., Hansen, U., Elsheikh, A., Malbouyres, M., Ricard-Blum, S., . . . Ruggiero, F. (2012). In Vivo Evidence for a Bridging Role of a Collagen V Subtype at the Epidermis–Dermis Interface. Journal of Investigative Dermatology, 132(7), 1841-1849. doi:10.1038/jid.2012.56

    DOI: 10.1038/jid.2012.56

    Stress free configuration of the human eye. (Journal article)

    Elsheikh, A., Whitford, C., Hamarashid, R., Kassem, W., Joda, A., & Büchler, P. (2013). Stress free configuration of the human eye.. Medical engineering & physics, 35(2), 211-216. doi:10.1016/j.medengphy.2012.09.006

    DOI: 10.1016/j.medengphy.2012.09.006

    Structural Engineers' Contribution to Eye Healthcare (Journal article)

    Elsheikh, A. (2012). Structural Engineers' Contribution to Eye Healthcare. Annual meeting of the Association for Science Education, 1, 1.

    2011

    Biometry of the Cornea in Myopic Chinese Patients (Journal article)

    Bao, F. -J., Yu, A. -Y., Kassem, W., Wang, Q. -M., & Elsheikh, A. (2011). Biometry of the Cornea in Myopic Chinese Patients. Journal of Refractive Surgery, 27(5), 345-355. doi:10.3928/1081597X-20101105-02

    DOI: 10.3928/1081597X-20101105-02

    Clinical evaluation of multi-parameter correction equations for Goldmann applanation tonometery (Journal article)

    Davey, P. G., Elsheikh, A., & Garway-Heath, D. F. (2011). Clinical evaluation of multi-parameter correction equations for Goldmann applanation tonometery. Eye, 27, 621-629. doi:10.1038/eye.2013.23

    DOI: 10.1038/eye.2013.23

    Corneal behaviour (Conference Paper)

    Elsheikh, A. (2011). Corneal behaviour. In The Royal College of Ophthalmologists Annual Congress. Birmingham.

    Corneal biomechanics and corneal ectasia (Conference Paper)

    Elsheikh, A. (2011). Corneal biomechanics and corneal ectasia. In UKISCRS meeting. Southport.

    Effect of Glucose on the Stress-Strain Behavior of ex-vivo Rabbit Cornea (Journal article)

    Ni, S., Yu, J., Bao, F., Li, J., Elsheikh, A., & Wang, Q. (2011). Effect of Glucose on the Stress-Strain Behavior of ex-vivo Rabbit Cornea. Experimental Eye Research, 92, 353-360.

    Inverse Finite Element Modelling of Posterior Human Sclera (Conference Paper)

    Geraghty, B., Kassem, W., Rama, P., & Elsheikh, A. (2011). Inverse Finite Element Modelling of Posterior Human Sclera. In Advances in Biomechanics and Mechanobiological Modelling. Oxford.

    Multiparameter Correction Equation for Goldmann Applanation Tonometry (Journal article)

    Elsheikh, A., Alhasso, D., Gunvant, P., & Garway-Heath, D. (2011). Multiparameter Correction Equation for Goldmann Applanation Tonometry. Optometry and Vision Science, 88(1), E102-E112. doi:10.1097/OPX.0b013e3181fc3453

    DOI: 10.1097/OPX.0b013e3181fc3453

    Ocular Biomechanics: Importance & Recent Developments (Conference Paper)

    Elsheikh, A. (2011). Ocular Biomechanics: Importance & Recent Developments. In Bowman Club Meeting. Royal College of Surgeons of Edinburgh.

    Strain-rate Sensitivity of Porcine and Ovine Corneas (Journal article)

    Elsheikh, A., Kassem, W., & Jones, S. W. (2011). Strain-rate Sensitivity of Porcine and Ovine Corneas. Acta of Bioengineering and Biomechanics, 13(2), 25-36.

    The Influence of Lamellar Orientation on Corneal Material Behavior: Biomechanical and Structural Changes in an Avian Corneal Disorder (Journal article)

    Boote, C., Elsheikh, A., Kassem, W., Kamma-Lorger, C. S., Hocking, P. M., White, N., . . . Meek, K. M. (2011). The Influence of Lamellar Orientation on Corneal Material Behavior: Biomechanical and Structural Changes in an Avian Corneal Disorder. Investigative Opthalmology & Visual Science, 52(3), 1243. doi:10.1167/iovs.10-5962

    DOI: 10.1167/iovs.10-5962

    Tonometry - Past, Present and Future (Chapter)

    Elsheikh, A. (2011). Tonometry - Past, Present and Future. In P. Gunvant (Ed.), Glaucoma - Current Clinical and Research Aspects (pp. 85-109). New York: InTech Publications.

    2010

    Biomechanics, Trends and Applications (Chapter)

    Elsheikh, A. (2010). Biomechanics, Trends and Applications. New York: Nova Publishers.

    Characterization of age-related variation in corneal biomechanical properties (Journal article)

    Elsheikh, A., Geraghty, B., Rama, P., Campanelli, M., & Meek, K. M. (2010). Characterization of age-related variation in corneal biomechanical properties. Journal of The Royal Society Interface, 7(51), 1475-1485. doi:10.1098/rsif.2010.0108

    DOI: 10.1098/rsif.2010.0108

    Estimation of Shear Strength of Structural Shear Walls (Journal article)

    Kassem, W., & Elsheikh, A. (2010). Estimation of Shear Strength of Structural Shear Walls. Journal of Structural Engineering, 136(10), 1215-1224. doi:10.1061/(ASCE)ST.1943-541X.0000218

    DOI: 10.1061/(ASCE)ST.1943-541X.0000218

    Finite Element Modeling of Corneal Biomechanical Behavior (Journal article)

    Elsheikh, A. (2010). Finite Element Modeling of Corneal Biomechanical Behavior. Journal of Refractive Surgery, 26(4), 289-300. doi:10.3928/1081597X-20090710-01

    DOI: 10.3928/1081597X-20090710-01

    Regional variation in the biomechanical properties of the human sclera (Journal article)

    Elsheikh, A., Geraghty, B., Alhasso, D., Knappett, J., Campanelli, M., & Rama, P. (2010). Regional variation in the biomechanical properties of the human sclera. Experimental Eye Research, 90(5), 624-633. doi:10.1016/j.exer.2010.02.010

    DOI: 10.1016/j.exer.2010.02.010

    2009

    Assessment of the ocular response analyzer as a tool for intraocular pressure measurement (Journal article)

    Elsheikh, A. (2009). Assessment of the Ocular Response Analyzer as a Tool for Intraocular Pressure Measurement. Journal of Biomechanical Engineering, 131(8), 081010. doi:10.1115/1.3148462

    DOI: 10.1115/1.3148462

    Corneal Changes in an Avian Inherited Retinal Dystrophy - Biomechanical Studies (Conference Paper)

    Boote, C., Elsheikh, A., Hocking, P. M., Hayes, S., Kamma-Lorger, C. S., Ali, M., . . . Meek, K. M. (2009). Corneal Changes in an Avian Inherited Retinal Dystrophy - Biomechanical Studies. In The 9th Cornea Conference. Cardiff.

    Goldmann Tonometry Correction Factors Based on Numerical Analysis (Journal article)

    Elsheikh, A., Alhasso, D., & Pye, D. (2009). Goldmann Tonometry Correction Factors Based on Numerical Analysis. Journal of Biomechanical Engineering, 131(11), 111013. doi:10.1115/1.4000112

    DOI: 10.1115/1.4000112

    Mechanical anisotropy of porcine cornea and correlation with stromal microstructure (Journal article)

    Elsheikh, A., & Alhasso, D. (2009). Mechanical anisotropy of porcine cornea and correlation with stromal microstructure. Experimental Eye Research, 88(6), 1084-1091. doi:10.1016/j.exer.2009.01.010

    DOI: 10.1016/j.exer.2009.01.010

    Nanopatterned Collagen Scaffolds Improve the Mechanical Properties of Tissue Engineered Vascular Grafts (Conference Paper)

    Zorlutuna, P., Elsheikh, A., & Hasirci, V. (2009). Nanopatterned Collagen Scaffolds Improve the Mechanical Properties of Tissue Engineered Vascular Grafts. In 22nd European Conference on Biomaterials. Lausanne, Switzerland.

    Nanopatterning of Collagen Scaffolds Improve the Mechanical Properties of Tissue Engineered Vascular Grafts (Journal article)

    Zorlutuna, P., Elsheikh, A., & Hasirci, V. (2009). Nanopatterning of Collagen Scaffolds Improve the Mechanical Properties of Tissue Engineered Vascular Grafts. Biomacromolecules, 10(4), 814-821. doi:10.1021/bm801307y

    DOI: 10.1021/bm801307y

    Numerical Study of the Effect of Corneal Layered Structure on Ocular Biomechanics (Journal article)

    Elsheikh, A., Ross, S., Alhasso, D., & Rama, P. (2009). Numerical Study of the Effect of Corneal Layered Structure on Ocular Biomechanics. Current Eye Research, 34(1), 26-35. doi:10.1080/02713680802535263

    DOI: 10.1080/02713680802535263

    Predictive Numerical Simulation of Ocular Behaviour - Potential in Clinical Practice and Necessity of Understanding Corneal Micro-structure (Conference Paper)

    Elsheikh, A., & Garway-Heath, D. F. (2009). Predictive Numerical Simulation of Ocular Behaviour - Potential in Clinical Practice and Necessity of Understanding Corneal Micro-structure. In The 9th Cornea Conference. Cardiff.

    Regional Biomechanical Behavior of the Human Sclera and its Variation with Age (Conference Paper)

    Elsheikh, A., Geraghty, B., Alhasso, D., & Rama, P. (2009). Regional Biomechanical Behavior of the Human Sclera and its Variation with Age. In Reducing disparities in Eye Disease and Treatment, ARVO Conference. Florida.

    Ultrastructural changes in the retinopathy, globe enlarged (rge) chick cornea (Journal article)

    Boote, C., Hayes, S., Young, R. D., Kamma-Lorger, C. S., Hocking, P. M., Elsheikh, A., . . . Meek, K. M. (2009). Ultrastructural changes in the retinopathy, globe enlarged (rge) chick cornea. Journal of Structural Biology, 166(2), 195-204. doi:10.1016/j.jsb.2009.01.009

    DOI: 10.1016/j.jsb.2009.01.009

    Variation of Corneal Biomechanics with Age - Characterisation & Implications on Predictive Modelling (Conference Paper)

    Geraghty, B., Alhasso, D., Rama, P., & Elsheikh, A. (2009). Variation of Corneal Biomechanics with Age - Characterisation & Implications on Predictive Modelling. In The 9th Cornea Conference. Cardiff.

    2008

    Assessment of the epithelium's contribution to corneal biomechanics (Journal article)

    Elsheikh, A., Alhasso, D., & Rama, P. (2008). Assessment of the epithelium's contribution to corneal biomechanics. Experimental Eye Research, 86(2), 445-451. doi:10.1016/j.exer.2007.12.002

    DOI: 10.1016/j.exer.2007.12.002

    Biomechanical properties of human and porcine corneas (Journal article)

    Elsheikh, A., Alhasso, D., & Rama, P. (2008). Biomechanical properties of human and porcine corneas. Experimental Eye Research, 86(5), 783-790. doi:10.1016/j.exer.2008.02.006

    DOI: 10.1016/j.exer.2008.02.006

    Experimental Assessment of Human Corneal Hysteresis (Journal article)

    Elsheikh, A., Wang, D., Rama, P., Campanelli, M., & Garway-Heath, D. (2008). Experimental Assessment of Human Corneal Hysteresis. Current Eye Research, 33(3), 205-213. doi:10.1080/02713680701882519

    DOI: 10.1080/02713680701882519

    Experimental assessment of corneal Anisotropy (Journal article)

    Elsheikh, A., Brown, M., Alhasso, D., Rama, P., Campanelli, M., & Garway-Heath, D. (2008). Experimental assessment of corneal Anisotropy. JOURNAL OF REFRACTIVE SURGERY, 24(2), 178-187. Retrieved from http://www.ncbi.nlm.nih.gov/

    Goldmann Applanation Correction Factors Based on Numerical Analysis (Paper presentation) (Conference Paper)

    Elsheikh, A., Pye, D., & Garway-Heath, D. (2008). Goldmann Applanation Correction Factors Based on Numerical Analysis (Paper presentation). In Eyes on Innovation, ARVO Conference. Florida.

    Tissue-Specific Expression of Collagen V Homotrimer (Conference Paper)

    Bonod-Bidaud, C., Roulet, M., Elsheikh, A., Faye, C., Malbouyres, M., Vaganay, E., . . . Ruggiero, F. (2008). Tissue-Specific Expression of Collagen V Homotrimer. In Meeting of Federation of European Connective Tissue Societies. Marseille, France.

    2007

    Assessment of Corneal Biomechanical Properties and Their Variation with Age (Journal article)

    Elsheikh, A., Wang, D., Brown, M., Rama, P., Campanelli, M., & Pye, D. (2007). Assessment of Corneal Biomechanical Properties and Their Variation with Age. Current Eye Research, 32(1), 11-19. doi:10.1080/02713680601077145

    DOI: 10.1080/02713680601077145

    Design simplifications in corneal engineering (Conference Paper)

    Elsheikh, A. (2007). Design simplifications in corneal engineering. In Tissue Engineering & Regenerative Medicine International Society, EU-Chapter meeting. London.

    Determination of the modulus of elasticity of the human cornea (Journal article)

    Elsheikh, A., Wang, D., & Pye, D. (2007). Determination of the modulus of elasticity of the human cornea. JOURNAL OF REFRACTIVE SURGERY, 23(8), 808-818. Retrieved from http://www.ncbi.nlm.nih.gov/

    Effect of Keratocyte Presence on the Mechanical Properties of Micropatterned Collagen Films (Conference Paper)

    Vrana, E., Elsheikh, A., Builles, N., Damour, O., & Hasirci, H. (2007). Effect of Keratocyte Presence on the Mechanical Properties of Micropatterned Collagen Films. In Society for Biomaterials Annual Meeting. Chicago, USA.

    Effect of human corneal keratocytes and retinal pigment epithelial cells on the mechanical properties of micropatterned collagen films (Journal article)

    Vrana, N. E., Elsheikh, A., Builles, N., Damour, O., & Hasirci, V. (2007). Effect of human corneal keratocytes and retinal pigment epithelial cells on the mechanical properties of micropatterned collagen films. Biomaterials, 28(29), 4303-4310. doi:10.1016/j.biomaterials.2007.06.013

    DOI: 10.1016/j.biomaterials.2007.06.013

    Influence of Keratocytes and RPE Cells on the Mechanical Properties of Polyester-Based Tissue Engineering Scaffolds (Conference Paper)

    Zorlutuna, P., Builles, N., Damour, O., Elsheikh, A., & Hasirci, V. (2007). Influence of Keratocytes and RPE Cells on the Mechanical Properties of Polyester-Based Tissue Engineering Scaffolds. In 21st European Conference on Biomaterials. Brighton, UK.

    Influence of keratocytes and retinal pigment epithelial cells on the mechanical properties of polyester-based tissue engineering micropatterned films (Journal article)

    Zorlutuna, P., Builles, N., Damour, O., Elsheikh, A., & Hasirci, V. (2007). Influence of keratocytes and retinal pigment epithelial cells on the mechanical properties of polyester-based tissue engineering micropatterned films. Biomaterials, 28(24), 3489-3496. doi:10.1016/j.biomaterials.2007.04.013

    DOI: 10.1016/j.biomaterials.2007.04.013

    Measurement of IOP (Chapter)

    Elsheikh, A. (2007). Measurement of IOP. In Intraocular Pressure: Consensus Series 4. The Hague, Netherlands: Kugler Publications.

    Numerical modelling of corneal biomechanical behaviour (Journal article)

    Elsheikh, A., & Wang, D. (2007). Numerical modelling of corneal biomechanical behaviour. Computer Methods in Biomechanics and Biomedical Engineering, 10(2), 85-95. doi:10.1080/10255840600976013

    DOI: 10.1080/10255840600976013

    Study of Corneal Biomechanics Using Structural Analysis Tools (Keynote Speech) (Conference Paper)

    Elsheikh, A. (2007). Study of Corneal Biomechanics Using Structural Analysis Tools (Keynote Speech). In 6th Int. Conf. Structural & Geotechnical Engineering. Alexandria, Egypt.

    Variation of Corneal Biomechanical Properties with Age (Paper presentation) (Conference Paper)

    Elsheikh, A., Wang, D., Brown, M., Rama, P., Campanelli, M., & Pye, D. (2007). Variation of Corneal Biomechanical Properties with Age (Paper presentation). In The Ageing Eye, ARVO Conference. Florida.

    2006

    Corneal Thickness- and Age-Related Biomechanical Properties of the Cornea Measured with the Ocular Response Analyzer (Journal article)

    Kotecha, A., Elsheikh, A., Roberts, C. R., Zhu, H., & Garway-Heath, D. F. (2006). Corneal Thickness- and Age-Related Biomechanical Properties of the Cornea Measured with the Ocular Response Analyzer. Investigative Opthalmology & Visual Science, 47(12), 5337. doi:10.1167/iovs.06-0557

    DOI: 10.1167/iovs.06-0557

    Evaluation of Goldmann Applanation Tonometry Using a Nonlinear Finite Element Ocular Model (Journal article)

    Elsheikh, A., Wang, D., Kotecha, A., Brown, M., & Garway-Heath, D. (2006). Evaluation of Goldmann Applanation Tonometry Using a Nonlinear Finite Element Ocular Model. Annals of Biomedical Engineering, 34(10), 1628-1640. doi:10.1007/s10439-006-9191-8

    DOI: 10.1007/s10439-006-9191-8

    Mathematical Modeling of the Biomechanics of the Lamina Cribrosa Under Elevated Intraocular Pressures (Journal article)

    Newson, T., & El-Sheikh, A. (2006). Mathematical Modeling of the Biomechanics of the Lamina Cribrosa Under Elevated Intraocular Pressures. Journal of Biomechanical Engineering, 128(4), 496. doi:10.1115/1.2205372

    DOI: 10.1115/1.2205372

    Patterned Collagen Film Multilayers as Artificial Corneal Stroma Substitute (Conference Paper)

    Vrana, E., Elsheikh, A., Builles, N., Damour, O., & Hasirci, H. (2006). Patterned Collagen Film Multilayers as Artificial Corneal Stroma Substitute. In 20th European Conference on Biomaterials. Nantes, France.

    Structural Assessment of Rapid Deployment Canopy Structure (Journal article)

    Elsheikh, A., & Gengnagel, C. (2006). Structural Assessment of Rapid Deployment Canopy Structure. Advances in Structural Engineering, 9(2), 241-256. doi:10.1260/136943306776987029

    DOI: 10.1260/136943306776987029

    2005

    Comparative study of corneal strip extensometry and inflation tests (Journal article)

    Elsheikh, A., & Anderson, K. (2005). Comparative study of corneal strip extensometry and inflation tests. Journal of The Royal Society Interface, 2(3), 177-185. doi:10.1098/rsif.2005.0034

    DOI: 10.1098/rsif.2005.0034

    Large-Deflection Mathematical Analysis of Rectangular Plates (Journal article)

    Wang, D., & Elsheikh, A. (2005). Large-Deflection Mathematical Analysis of Rectangular Plates. Journal of Structural Engineering, ASCE, 131(8).

    The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry (Journal article)

    Tonnu, P. -A. (2005). The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry. British Journal of Ophthalmology, 89(7), 851-854. doi:10.1136/bjo.2004.056622

    DOI: 10.1136/bjo.2004.056622

    2004

    Application of structural analysis to the mechanical behaviour of the cornea (Journal article)

    Anderson, K., El-Sheikh, A., & Newson, T. (2004). Application of structural analysis to the mechanical behaviour of the cornea. Journal of The Royal Society Interface, 1(1), 3-15. doi:10.1098/rsif.2004.0002

    DOI: 10.1098/rsif.2004.0002

    FEA of the Biomechanics of Porcine Cornea (Journal article)

    Anderson, K., Elsheikh, A., & Newson, T. (2004). FEA of the Biomechanics of Porcine Cornea. Journal of Structural Engineer, 82(12), 20-25.

    2003

    Mathematical Modelling of the Effect of Elevated Intra-ocular Pressure on the Lamina Cribrosa (Conference Paper)

    Newson, T., Elsheikh, A., & Hamza, O. (2003). Mathematical Modelling of the Effect of Elevated Intra-ocular Pressure on the Lamina Cribrosa. In G. Turkiyyah (Ed.), 16th ASCE Engineering Mechanics Conference (pp. 1). Seatle.

    Modelling the Biomechanical Effects of Increasing Intra-ocular Pressure on the Porcine Cornea (Conference Paper)

    Anderson, K., Elsheikh, A., & Newson, T. (2003). Modelling the Biomechanical Effects of Increasing Intra-ocular Pressure on the Porcine Cornea. In G. Turkiyyah (Ed.), 16th ASCE Engineering Mechanics Conference (pp. 1). Seatle.

    2002

    Behaviour of Curved and Continuous Compression Members (Journal article)

    Zien-Eldin, H., Elsheikh, A., & Smith, F. W. (2002). Behaviour of Curved and Continuous Compression Members. Engineering Structures, 24(12), 1499-1507.

    Effect of Geometric Imperfections on Single-Layer Barrel Vaults (Journal article)

    Elsheikh, A. (2002). Effect of Geometric Imperfections on Single-Layer Barrel Vaults. International Journal of Space Structures, 17(4), 271-283.

    Finite Element versus Traditional Techniques for Least Square Adjustment of Levelling Networks (Conference Paper)

    Al-Oumar, A., & Elsheikh, A. (2002). Finite Element versus Traditional Techniques for Least Square Adjustment of Levelling Networks. In 6th Int. Symp. on Environmental Geotechnology and Global Sustainable Development. Soul, Korea.

    Lightweight Structures Based on Curved and Continuous Chord Members (Conference Paper)

    Elsheikh, A. (2002). Lightweight Structures Based on Curved and Continuous Chord Members. In J. B. Obrebski (Ed.), IASS Conference (pp. 227-232). Warsaw.

    Performance of Curved Space Structures (Conference Paper)

    Elsheikh, A., & El-Kassas, E. M. A. (2002). Performance of Curved Space Structures. In G. R. Parke, & P. Disney (Eds.), 5th Int. Conf. Space Structures (pp. 1129-1138). Surrey.

    Using Neural Networks to Predict the Design Load of Cold-Formed Steel Compression Members (Journal article)

    El-Kassas, E. M. A., Mackie, R., & Elsheikh, A. (2002). Using Neural Networks to Predict the Design Load of Cold-Formed Steel Compression Members. Advances in Engineering Software, 32, 713-719.

    2001

    Configurations of Single-Layer Barrel Vaults (Journal article)

    Elsheikh, A. (2001). Configurations of Single-Layer Barrel Vaults. International Journal of Advances in Structural Engineering, 4(2), 53-64.

    Performance of Single-Layer Barrel Vaults with Different Configurations (Journal article)

    Elsheikh, A. (2001). Performance of Single-Layer Barrel Vaults with Different Configurations. International Journal of Space Structures, 16(2), 111-123.

    Performance of Stiffened and Unstiffened Cold-Formed Channel Members in Axial Compression (Journal article)

    Elsheikh, A., El-Kassas, E. M. A., & Mackie, R. I. (2001). Performance of Stiffened and Unstiffened Cold-Formed Channel Members in Axial Compression. Engineering Structures, 23(10), 1221-1231.

    Using Neural Networks in Cold-Formed Steel Design (Journal article)

    El-Kassas, E. A., Mackie, R. I., & Elsheikh, A. (2001). Using Neural Networks in Cold-Formed Steel Design. Computers and Structures, 79(18), 1687-1696.

    Using Neural Networks to Design Cold-Formed Steel Sections (Conference Paper)

    Mackie, R. I., El-Kassas, E. M. A., & Elsheikh, A. (2001). Using Neural Networks to Design Cold-Formed Steel Sections. In B. H. V. Topping, & B. Kumar (Eds.), 6th Int. Conf. Application of Artificial Intelligence to Civil & Struct. Engng (pp. 18). Stirling: Civil-Comp Press.

    2000

    Approximate Dynamic Analysis of Space Trusses (Journal article)

    Elsheikh, A. (2000). Approximate Dynamic Analysis of Space Trusses. Engineering Structures, 22(1), 26-38.

    Behaviour of Space Frame Roof Structures with Direct Member Loading (Journal article)

    Elsheikh, A. (2000). Behaviour of Space Frame Roof Structures with Direct Member Loading. Journal of International Association for Shell and Spatial Structures, 41(2), 75-90.

    Configurations of Braced Domes (Journal article)

    Elsheikh, A. (2000). Configurations of Braced Domes. International Journal of Advances in Structural Engineering, 3(3), 231-244.

    Effect of Direct Member Loading on Space Truss Behaviour (Journal article)

    Elsheikh, A. (2000). Effect of Direct Member Loading on Space Truss Behaviour. Structural Engineering and Mechanics, 10(1), 1-15.

    Neural Networks and Cold-Formed Steel Design (Conference Paper)

    El-Kassas, E. M. A., Mackie, R. I., & Elsheikh, A. (2000). Neural Networks and Cold-Formed Steel Design. In B. H. V. Topping (Ed.), 5th Int. Conf. Engng Computational Technology (pp. 37-44). Leuven: Civil-Comp Press.

    New Space Truss System - From Concept to Implementation (Journal article)

    Elsheikh, A. (2000). New Space Truss System - From Concept to Implementation. Engineering Structures, 22(9), 1070-1085.

    1999

    Assessment of Composite Steel/Concrete Bridges with a Triangular girder configuration (Conference Paper)

    Elsheikh, A., & Abbas, H. (1999). Assessment of Composite Steel/Concrete Bridges with a Triangular girder configuration. In 6th Int. Conf. Steel & Space Structures (pp. 231-237). Singapore.

    Comparative Studies of Double- and Triple-Layer Space Trusses (Journal article)

    Elsheikh, A. (1999). Comparative Studies of Double- and Triple-Layer Space Trusses. Structural Engineering and Mechanics, 8(4), 383-399.

    Design of Top Concrete Slabs of Composite Space Trusses (Journal article)

    Elsheikh, A. (1999). Design of Top Concrete Slabs of Composite Space Trusses. Structural Engineering and Mechanics, 7(3), 319-330.

    Design of Web Members in Space Trusses (Journal article)

    Elsheikh, A. (1999). Design of Web Members in Space Trusses. International Journal of Space structures, 14(1), 25-34.

    Experimental Study of Composite Space Trusses With Continuous Chords (Journal article)

    Elsheikh, A., & Shaaban, H. (1999). Experimental Study of Composite Space Trusses With Continuous Chords. International Journal of Advances in Structural Engineering, 2(3), 219-232.

    Failure Mode and Strength of Space Truss Compression Chord Members (Journal article)

    Elsheikh, A. (1999). Failure Mode and Strength of Space Truss Compression Chord Members. Engineering Structures, 21(5), 395-405.

    Optimum Design of Composite Space Trusses (Journal article)

    Elsheikh, A. (1999). Optimum Design of Composite Space Trusses. Journal of International Association for Shell and Spatial Structures, 40(2), 79-92.

    1998

    Configurations of Double-Layer Space Truss (Journal article)

    Elsheikh, A. (1998). Configurations of Double-Layer Space Truss. Structural Engineering and Mechanics, 6(5), 543-554.

    Design of Space Truss Structures (Journal article)

    Elsheikh, A. (1998). Design of Space Truss Structures. Structural Engineering and Mechanics, 6(2), 185-200.

    Effect of Force Limiting Devices on Behaviour of Space Trusses (Journal article)

    Elsheikh, A. (1998). Effect of Force Limiting Devices on Behaviour of Space Trusses. Engineering Structures, 12(1), 34-44.

    Optimum Design of Space Trusses (Journal article)

    Elsheikh, A. (1998). Optimum Design of Space Trusses. Journal of International Association for Shell and Spatial Structures, 39(3), 159-168.

    1997

    Composite Space Truss Bridges (Conference Paper)

    Elsheikh, A., & Abbas, H. (1997). Composite Space Truss Bridges. In 4th Int. Kerensky Conf. Structures in the New Millennium (pp. 493-497). Hong Kong.

    Development of a New Low Cost Space Frame System (Conference Paper)

    Elsheikh, A. (1997). Development of a New Low Cost Space Frame System. In Al-Azhar 5th Int. Engng Conference (pp. 316-326). Cairo, Egypt.

    Effect of member length imperfections on triple-layer space trusses (Journal article)

    El-Sheikh, A. (1997). Effect of member length imperfections on triple-layer space trusses. Engineering Structures, 19(7), 540-550. doi:10.1016/S0141-0296(96)00120-4

    DOI: 10.1016/S0141-0296(96)00120-4

    Effect of spandrel beams on strength and behaviour of column-slab connections (Journal article)

    EI-Sheikh, A. (1997). Effect of spandrel beams on strength and behaviour of column-slab connections. Magazine of Concrete Research, 49(180), 221-230. doi:10.1680/macr.1997.49.180.221

    DOI: 10.1680/macr.1997.49.180.221

    Sensitivity of Space Trusses to Sudden Member Loss (Journal article)

    Elsheikh, A. (1997). Sensitivity of Space Trusses to Sudden Member Loss. International Journal of Space Structures, 12(1), 31-41.

    Shear Interaction Between Space Trusses and Timber Boards (Journal article)

    Elsheikh, A., & Shaaban, H. (1997). Shear Interaction Between Space Trusses and Timber Boards. Journal of International Association for Shell and Spatial Structures, 38(3), 155-164.

    Triangular Grid Decks for Composite Roadway Bridges (Conference Paper)

    Abbas, H., & Elsheikh, A. (1997). Triangular Grid Decks for Composite Roadway Bridges. In 4th Int. Kerensky Conf. Structures in the New Millennium (pp. 487-491). Hong Kong.

    1996

    Application of Expert System Technology in the Design of Bridges (Conference Paper)

    Elsheikh, A. (1996). Application of Expert System Technology in the Design of Bridges. In 1st Int. Conf. Computing and Information Technology for Arch., Engng & Construction Vol. 1 (pp. 105-112). Singapore.

    Approximate Analysis of Space Trusses (Journal article)

    Elsheikh, A. (1996). Approximate Analysis of Space Trusses. International Journal of Space Structures, 11(3), 321-330.

    Assessment of the Behaviour of Bellabeg Old Metal Bridge (Conference Paper)

    Elsheikh, A., & Harvey, W. J. (1996). Assessment of the Behaviour of Bellabeg Old Metal Bridge. In 5th Int. Coll. Structural Stability (pp. 135-145). Brazil.

    Competitiveness of Composite Space Trusses with Continuous Chord Members (Journal article)

    Elsheikh, A., & Shaaban, H. (1996). Competitiveness of Composite Space Trusses with Continuous Chord Members. International Journal of Structures, 16(1), 38-56.

    Development of a new space truss system (Journal article)

    ElSheikh, A. (1996). Development of a new space truss system. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 37(3), 205-227.

    Effect of Composite Action on Space Truss Behaviour: Overview (Journal article)

    Elsheikh, A. (1996). Effect of Composite Action on Space Truss Behaviour: Overview. International Journal of Structures, 16(2), 57-72.

    Experimental Study of Behavior of New Space Truss System (Journal article)

    El-Sheikh, A. I., & El-Bakry, H. (1996). Experimental Study of Behavior of New Space Truss System. Journal of Structural Engineering, 122(8), 845-853. doi:10.1061/(ASCE)0733-9445(1996)122:8(845)

    DOI: 10.1061/(ASCE)0733-9445(1996)122:8(845)

    Sensitivity of Space Trusses to Uneven Support Settlement (Journal article)

    Elsheikh, A. (1996). Sensitivity of Space Trusses to Uneven Support Settlement. International Journal of Space Structures, 11(4), 393-400.

    Study of Shear Interaction Efficiency in a New Space Truss System (Conference Paper)

    Shaaban, H., Elsheikh, A., & Hegab, H. (1996). Study of Shear Interaction Efficiency in a New Space Truss System. In 7th Int. Coll. Struct. and Geo. Engng Vol. 3 (pp. 409-419). Ain Shams, Egypt.

    1995

    An Introduction to Drawing for Civil Engineers (Book)

    Elsheikh, A. (1995). An Introduction to Drawing for Civil Engineers. London, New York: McGraw Hill Book Company Europe.

    Competitiveness of Space Trusses with Continuous Chord Members (Journal article)

    Elsheikh, A., & El-Bakry, H. (1995). Competitiveness of Space Trusses with Continuous Chord Members. International Journal of Structures, 15(2), 98-117.

    Design of Slab Bridges (Journal article)

    Elsheikh, A. (1995). Design of Slab Bridges. International Journal of Structures, 15(1), 1-17.

    Sensitivity of Space Trusses to Member Geometric Imperfections (Journal article)

    Elsheikh, A. (1995). Sensitivity of Space Trusses to Member Geometric Imperfections. International Journal of Space Structures, 10(2), 89-98.

    1994

    Nonlinear Numerical Analysis of Composite Space Trusses (Journal article)

    Elsheikh, A. (1994). Nonlinear Numerical Analysis of Composite Space Trusses. International Journal of Space Structures, 9(4), 219-226.

    Sensitivity of Composite and Non-Composite Space Trusses to Member Loss (Journal article)

    Elsheikh, A. (1994). Sensitivity of Composite and Non-Composite Space Trusses to Member Loss. International Journal of Space Structures, 9(2), 107-119.

    1993

    Application of Substructuring in Space Trusses Using Pyramidal Structural Units (Conference Paper)

    Elsheikh, A., & Kwan, A. S. K. (1993). Application of Substructuring in Space Trusses Using Pyramidal Structural Units. In 5th Int. Conf. Civil and Struct. Engng Computing Vol. 1 (pp. 263-277). Edinburgh.

    Experimental Study of Behavior of Composite Space Trusses (Journal article)

    El‐Sheikh, A. I., & McConnel, R. E. (1993). Experimental Study of Behavior of Composite Space Trusses. Journal of Structural Engineering, 119(3), 747-766. doi:10.1061/(ASCE)0733-9445(1993)119:3(747)

    DOI: 10.1061/(ASCE)0733-9445(1993)119:3(747)

    Experimental Study of the Behaviour of Typical Space Frame Joints (Conference Paper)

    Elsheikh, A., & McConnel, R. E. (1993). Experimental Study of the Behaviour of Typical Space Frame Joints. In 4th Int. Conf. Space Structures Vol. 1 (pp. 1920-1928). Surrey.

    Numerical Analysis of Space Trusses with Flexible Member-End Joints (Journal article)

    Elsheikh, A. (1993). Numerical Analysis of Space Trusses with Flexible Member-End Joints. International Journal of Space Structures, 8(3), 189-197.

    1992

    Stiffness Expressions for Element with Central and End Springs (Journal article)

    McConnel, R. E., & El‐Sheikh, A. I. (1992). Stiffness Expressions for Element with Central and End Springs. Journal of Structural Engineering, 118(4), 955-969. doi:10.1061/(ASCE)0733-9445(1992)118:4(955)

    DOI: 10.1061/(ASCE)0733-9445(1992)118:4(955)

    1991

    Effect of Composite Action on Space Trusses (Conference Paper)

    McConnel, R. E., & Elsheikh, A. (1991). Effect of Composite Action on Space Trusses. In Int. Conf. Steel and Aluminium Structures Vol. 1 (pp. 94-103). Singapore.

    1990

    A Study of Shear Interaction Efficiency in Composite Space Truss Systems (Conference Paper)

    McConnel, R. E., & Elsheikh, A. (1990). A Study of Shear Interaction Efficiency in Composite Space Truss Systems. In 1st Conf. Struct. Engng and Geo. Problems, Alexandria, Egypt Vol. 1 (pp. 409-419).

    1989

    Effect of Marginal Beam on Strength and Behaviour of Column-Slab Connections (Conference Paper)

    Helmy, M., Korish, I., & Elsheikh, A. (1989). Effect of Marginal Beam on Strength and Behaviour of Column-Slab Connections. In 2nd East Asia-Pacific Conf. Struct. Engng and Construction, Thailand Vol. 1 (pp. 432-438).
    Untitled Document