New JetDose project set to optimise proton beam cancer therapy

Published on

Experts from the University of Liverpool have been awarded Science and Technology Facilities Council (STFC) funding to develop a novel monitoring system to help optimise proton beam cancer therapy. The new JetDose project will involve close collaboration between Liverpool, the company D-Beam, experts from the Clatterbridge Cancer Centre (CCC), Fondazione CNAO, and IBA in Belgium. It is a direct result from the successful research collaboration between those institutions within OMA.

Proton beam cancer therapy relies upon knowledge of the detailed beam properties to ensure effective dose delivery to the patient. Clinical settings currently use interceptive ionization chambers which require daily calibration and suffer from slow response times. With new and emerging treatment techniques using ultra high dose rates, there is a demand for the development of novel beam monitors, which are fast, non-invasive and calibration-free.

The Liverpool experts will carry out a cutting-edge research program into a novel monitor that will enable non-invasive in-vivo beam dosimetry in hadron beam cancer therapy. The project is led by OMA Coordinator Professor Carsten P Welsch and is supported by a £330k award from STFC’s Challenge Led Applied Systems Programme (CLASP).

Current methods to carry out beam characterisation require multiple systems each imparting a slight disturbance to the particle beam as it passes by. This disturbance can alter the intended transverse dose profile of the beam, ultimately creating slight deviations from a patient's treatment plan. Quality assurance methods are mostly disruptive measurements and do not allow treatment to take place at all whilst they are being conducted. JetDose will develop a new in-vivo dosimetry system based on the re-application of technologies pioneered by Professor Welsch’s QUASAR Group.

The underpinning technology was originally developed for use with low energy antiproton beams and most recently adapted for gas jet profiling for the high luminosity upgrade of the Large Hadron Collider at CERN. In this system, a supersonic gas jet is fired across the high intensity proton beam at the LHC. The gas molecules have little-to-no effect on the proton beam, however the proton beam excites the gas molecules; this excitation can be imaged, which is turn provides a complete non-invasive two-dimensional profile image of the proton beam.

JetDose will redirect this technology at the medical accelerator sector, by optimising it for the different challenges found in a treatment facility. The non-invasive means of producing a profile image will allow the monitor to be run online alongside treatment operation. As the intensity in the images directly depends upon the beam intensity, and therefore the dose, an image collected with this system provides an in-vivo dose map of the beam being delivered to the patient.

gas jet monitor

Photograph of gas jet-based beam monitor prototype at the Cockcroft Institute.

Professor Welsch said: “JetDose will produce a novel monitoring system which addresses the growing need for in-vivo dosimetry in medical facilities across the world. This technology also shows good promise for application at other high intensity, high energy particle accelerators and this wider market will be assessed as part of the business plan that will be developed. The project marks an important step in the physics department’s impact strategy.”